Evaluation of Turbidometric hsCRP Kits Commercially Available in India for Cardiovascular Risks Estimation
Keywords:
hsCRP-High Sensitive C-Reactive protein, SD-Standard deviation, C.V-Coefficient of variation, immunoturbidometryAbstract
The aim of the present study is to evaluate four turbidimetric assays, available in India, suited for Clinical chemistry analyzers; the analytical performances were measured with in the concentration range 0.32–7.5 mg/L, which has been proposed for cardiovascular risk assessment. Our study is comprised of four internationally accepted brands of immunoturbidimetric kits used for High Sensitive C- Reactive Protein (hs-CRP) estimation. Twenty different concentrations were analyzed over a period of 6 days to study the standard deviation (SD) and Coefficient of Variation (CV), using automated analyzer Miura. Significantly higher SD and CV% was observed in the lower concentrations of samples and lower SD were more or less the same over the period of 6 days. The sensitivity of Roche kit was found to be better with a low SD and CV%, in the low concentration samples. The study shows that there is a difference in the sensitivity and detection capacity of kits, the repeatability and the variation is also seen varying from lower to higher concentration, the variation is more marked in the case of low concentration samples when compared to the variation in the high concentration samples
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is notpublished already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
_______________
We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |