Estimation of Splenic Volume: Prolate Ellipsoid Method Correlated with 3-D Helical CT Determination
Keywords:
Spleen, volume, helical CT, sonography, prolate ellipsoid formulaAbstract
To establish the correlation between two methods of volume estimation of spleen, e.g., prolate ellipsoid formula and 3-D reconstruction of abdominal helical CT-image. Settings and Design: One hundred twenty-six patients were selected aged between 20 and 80 years in which male and female were 72 and 54 respectively for cross-sectional study. Patients who had underlying malignancy, infections, hematological disorders and other conditions that could alter splenic size were excluded. Methods and Material: Total volume of spleen in each patient was obtained by summation of stacks of images with the help of volume and surface rendering technique of Able 3-D doctor software. Other dimensions, e.g., length, width, and thickness were also obtained. Then volume of spleen was calculated by prolate ellipsoid method of each patient by using length, width and thickness. Then two methods were correlated by application of linear regression model. Results: The mean volume calculated by prolate ellipsoid formula was 288 ± 142.6 cm³. Splenic volume measured by prolate ellipsoid formula well correlated with volume measured by 3-D reconstruction of abdominal CT images (161.57 ± 90.2 cm³). We had developed the regression formula of ellipsoid splenic volume (cm³) = 1.224 × true splenic volume (cm³) + 61.49 (r = 0.929, p < 0.001). Conclusions: By CT-scan or sonographic measurements, prolate ellipsoid formula 0.524 × length × width × thickness provides best accuracy with helical CT determination of splenic volume. Above regression formula would be used to calculate the volume of spleen if helical CT is not used and would help in predicting diagnosis of splenomegaly in suspected clinical conditions.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is notpublished already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
_______________
We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |